Skip to main content
Canada HVAC β€” Serving all 10 provinces
Error codes Β· Goodman

Goodman Furnace 4 Flashes β€” Open High Limit

Four flashes on many Goodman boards means the high-limit switch opened during a heat call. Like Carrier’s code 33, this is almost always dirty filters, closed registers, or a struggling blower β€” not a reason to jumper the limit.

Updated July 2026 Β· 5 min read Β· Canada

Symptoms

  • Burners light, then shut down mid-cycle
  • LED pattern is 4 flashes (confirm door chart)
  • Supply air feels weak or rooms stay cold

Likely causes

  • Clogged 1" filter
  • Closed bedroom supplies or blocked return
  • Blower wheel packed with dust
  • Failed limit switch after chronic overheating

What to do

1. Match the flash count to the door sticker

Goodman revisions differ. Confirm 4 flashes = open limit before buying parts.

2. Replace the filter and restore airflow

Use the exact nominal size. If you recently installed a thick MERV-13 in a 1" slot, try MERV-11.

3. Reset and observe one heat cycle

If the furnace completes the cycle, maintain a monthly filter check for the rest of the season.

Stop and call a pro when

  • Flashes continue with a clean filter and open ducts
  • The heat exchanger shows rust-through or cracks
  • You need static-pressure diagnostics
  • Goodman 3 Flashes β€” Diagnose Goodman (and Amana) furnace LED 3-flash codes: pressure switch, inducer, and flame-sensing failures β€” plus the parts that usually fix them.
  • Carrier Code 33 β€” What Carrier furnace error code 33 means, how to safely check airflow and the limit switch, and which parts or filters usually clear the fault.
  • Replace 20Γ—25Γ—1 Filter β€” Step-by-step 20x25x1 furnace filter replacement with MERV tips and multipack product links for the exact size.
  • Carrier Code 13 β€” Carrier/Bryant code 13 is a limit lockout after repeated trips. Fix airflow first, then check filters or capacitors.

FAQ

Can I tape over the limit switch?

Never. Bypassing a limit can crack the heat exchanger and create a carbon monoxide hazard.

Need a licensed tech instead?

If the guide says to stop β€” or the part swap did not clear the fault β€” get free quotes from licensed local HVAC contractors.

Get matched with a pro